Unicook

Understanding the Multisensor indicator light signals

Airis Multisensor indicator light signals

The table below details the meanings of the Multisensor's indicator light signals:

LED colour Sound Function
Red flashing fast Yes, high-pitched Dangerous cooking detected
Red flashing (single) Yes, low-pitched three tone Battery low
Blue flashing (single) No Airis Multisensor is looking for a Bluetooth connection to a mobile device.
Blue light, constant No Multisensor is in firmware update mode. Keep your device close and do not shut down the Safera App during firmware update.
Blue flashing (single) Yes, medium-pitched three tone Water leakage alarm (requires additional leakage sensor).
Blue flashing (double) No Problem with the PCU.
Blue flashing (triple) No PCU overheating or other malfunction.
Green light, constant No Multisensor is entering software update mode. If the green light does not turn blue in two minutes, remove and re-insert batteries.
Purple light, constant No Multisensor is in Optional Accessory Pairing Mode.
Yellow light, constant No Factory reset in progress. This may take a couple of minutes.
Yellow light flashing (single) No Problem with sensors.
Yellow light flashing (double) No Problem with Multisensor electronics or software.
Yellow light flashing (triple) No Faulty installation of the Multisensor. Ensure that the Multisensor is mounted on a level surface at the correct distance from the stove.